One-Step Gonorrhea Rapid Test Kits

Type: Test Strips & Test Tube
Ethylene Oxide Sterilization: Ethylene Oxide Sterilization
Quality Guarantee Period: Two Years
Group: All
Logo Printing: Without Logo Printing
Transport Package: Standard Packaging
Customization:
Gold Member Since 2012

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
RF
Trademark
RF
Origin
Jiangsu, China
Production Capacity
10000000 Pieces/Year

Product Description

One-step Gonorrhea Rapid Test Kits

One-Step Gonorrhea Rapid Test Kits

This product is used for qualitative detection of the presence of Gonorrhea in female cervix and male urethra, and the clinical auxiliary diagnosis of Gonorrhea infection, and test results also need to be further confirmed by the clinician in connection with symptoms, signs and other test results.

Detection Principle

Gonorrhea diagnostic kit uses highly specific antigen antibody reaction and immune chromatography analysis techniques for the qualitative detection of whether clinical specimens contain Gonorrhea trachomatis antigen, and the kit contains Gonorrhea trachomatis antigen specific antibodies, which are prefixed on the test area (T) on the membrane, and the corresponding antibodies on the quality control area (C). During the detection, the pyrolysis off specimens on the cotton swab are titrated into the sampling wells (S) of the kit, and the specimens make a specific antibody reaction with the Gonorrhea trachomatis antigen of the precoated gold particles. Then, the mixture followed up with upward chromatography under capillary effect. If it is positive, gold labeled Gonorrhea will first bind with Gonorrhea trachomatis antigen in the specimens in the chromatography process, then the bonder will be combined by specific antibody of Gonorrhea trachomatis antigen, which is fixed on the membrane, and within the test area (T) there will appear a red band. If it is negative, there will no red band within the test area (T). Regardless of whether the Gonorrhea trachomatis antigen exists in clinical samples, there will be a red band within the quality control area (C). The red band within the quality control area (C) is to determine whether there is sufficient sample, and whether the process of chromatography is in line with the normal standards, and at the same time it is used as the internal control standards of the agent.

Major component ingredients

  1. Gonorrhea diagnostic kitA copy of operating instructionExtraction Solution AExtraction Solution B

Sample collection

The quality of the collected specimens is of paramount importance for Gonorrhea detection. The detection quality of Gonorrhea depends on the accurate sample collection techniques, which should make samples contain a large number of a certain active cellular components, and the samples should not just contain body fluids.

Female cervical sampling:

  1. Use sterile cervical swabs, or sterile linen, polyester swabs. Before sampling, wipe mucus of the cervical extraoral region with other swabs or cotton balls, and insert the sampling swab into the cervical tube through the squamous columnar epithelium junction, until the swab head has been virtually invisible. After rotating swab for 15-20 seconds, take it out, and do not hit the outside of the cervix and vaginal wall. This will ensure to get more columnar epithelial cells, while the Gonorrhea mainly parasite in columnar epithelial cells.Cervical samples can also be collected by the use of cell brush (not provided) (Note: Pregnant women should not use this method). After cleaning the cervical extraoral region, insert a cell brush into the cervical tube, through the scale columnar epithelial cells junction, and stay for 2-3 seconds, and after two cycles of rotating brush cells, take it out, and be careful not to hit the vaginal wall.If the detection can be immediately carried out, please place the swab in the samples processing tube after sampling.

Male urethral specimen collection:

Urethral use swabs or cells brush (not provided) can be used for urethral sampling. Patients should not urinate within at least 1 hour before sampling.

Insert the swab or cell brush into the urethra for 2~4 cm, and after rotating for 3~5 seconds, take it out. If the detection can be immediately carried out, please place the swab in the samples processing tube after sampling. If you don't take an immediate test, place the sample in dry test tube for storage or transportation.

Sample can be kept for 4-6 hours at room temperature (15-30 ºC), or (2-8 ºC) kept under cold storage for 24~72 hours. It can not be frozen. All specimens should revert to room temperature before detection. We propose that the experiment should be made immediately after sample collection.

Test procedure

  1. Samples processing and control:
    processing of cervical swabs and urethral swabs:

 Place the sample processing tubes on the worktable, and add 6 drops of extraction solution A.

Put the sampling swab into the sample processing tube, which contains extraction solution A, and store at room temperature, and continuously rotate and squeeze the swab in the tube wall in the process, so that the liquid is constantly being squeezed out, and repeat it for several times and deal with it for 2 minutes.

 Then add 6 drops of extraction solution B, and rotate and squeeze swab, as far as possible make the liquid flow out, and then discard the swab in line with the handling method of infected goods.

 If the samples shall be used, within 60 minutes after treated, this will not affect detection results of the kit.

Notes: The dropping amount of solution A and extraction solution B should be equal, when the swabs is processed 
B. Detection steps: 

  1. Please read the instructions for the test kit carefully before operation.Take out the test kit from the sealed bag, and place it in a clean, dry and level worktable, and label the sample number or name. If the test kit is stored at the place, which temperature is lower than room temperature, and the test kits and reagents required to be taken out in advance, and it should revert to room temperature before it is being used.2 ~3 drops of processed samples in the sample processing tube should be dripped into the sampling wells of the test kit.Wait for the appearance of the results. 10 minutes after the sample is dripped, the results can be interpreted. The time of the red line varies in line with the contents of Gonorrhea, which is collected with swabs, and some positive samples may show the result after 60 seconds. In order to ensure the negative results, please do not judge the result after 15 minutes.

Results determination

Positive: Two purple bands appear at the test line and the control line of the test card. The positive results show that: samples contain Gonorrhea trachomatis antigen.

Negative: Only one purple band appears at the control line of the test paper card. Negative results show that: Gonorrhea trachomatis antigen can't be detected in samples, or the content is below the detectable range. Patient specimens should be confirmed no Gonorrhea trachomatis infection by culture. If the culture results and test results are inconsistent, and take another sample to culture.

Invalid: If there is no purple band at the control line, it indicates that the operation course is incorrect or the kit fails. In this case, please re-read the instructions carefully and use the new test paper cards for re-test. If there are still problems, the batch product should be immediately stopped use, and please contact with local suppliers.

The interpretation of test results

  1. The purple bands, which appear at the control line, is used as the internal control standards of the test paper strip.The purple bands appear gradation phenomenon at the testing line, when testing different specimens, and this is due to high and low concentrations of surface antigen. However, within the specified time, regardless of the depth of the ribbon color, even if only a very weak ribbon should also be judged as positive results.

The limitations of the testing methods

  1. The detection of Gonorrhea trachomatis with this kit depends on the content of Gonorrhea in the sample, sampling methods and the patient's condition: such as age, venereal disease history, whether there is symptom and other conditions shall affect the detection.If determining the Gonorrhea of different serotypes with this kit, the minimum detectable level shall be also different.May be due to operational improper of technology or steps, and the presence of other non-listed drugs, which may interfere with detection, and it shall interfere with detection and lead to inconsistent or erroneous results. Please refer to the column [Performance indicators of products]to look over the list of substances that could interfere with detection.

Performance indicators of products

  1. Only used by extrinsic diagnosis and professionals.Do not use after the expiry,Don't mix and match different batches of reagents or test kits; Do not mix the lids of solutions A and B.The collection, processing, storage, discarding of the sample and the use of the reagent in the kit should take appropriate precautions. All the samples, reagents, and control substance should be handled as infectious substances.After the completion of the test, the sample shall be sterilized at 121 ºC high temperature for 20 minutes, or use 0.5-1.0% sodium hypochlorite (or household bleach) to soak for 1 hour before discarded.Extraction solution A contains sodium hydroxide, and extraction solution B contains hydrochloric acid, if these two solutions are splashed on the skin or in eyes, we should rinse immediately with plenty of water.Can only collect samples with sterile Dacron swab or cell brush, and cotton swab sampling is not available.The region of dealing with sample and reagent prohibits eating, drinking and smoking; when collecting and testing samples, you should wear an experimental clothing and gloves.The final diagnosis of the patient can not simply rely on the results of this experiment, the comprehensive judgments must be made combined with clinical examination by a doctor. 

Storage conditions and valid period

Preserve at 2-30 ºC in sealed dark dry place, and the valid period is 24 months.

References

  1. Control practical handbook for bio-products and their quality standards for raw and auxiliary materials, Volume III, national audio-visual publishing house, Miao Yong, Zang Guangzhou editor in chief.The preparation instructions for extrinsic diagnostic reagents guideline; State Food Drug Administration Device [2007] No. 240.
About us

Refine Medical Technology Co., Ltd. was founded in Nanjing, China with the goal to supply medical products with high quality, competitive price and excellent after-sales service.
 
As the leading professional manufacturer & exporter of medical equipment, Refine Medical own a group of very professional technical and sales staff with the high efficiency, who are able to provide the customers complete range of service. Being approved with CE,ISO, Certificate, etc. We have established efficient worldwide network of marketing. In the past 15 years, we have exported our products to more than 120 countries all over the world. 
 
Refine Medical product range covers X-ray machines, Ultrasound Scanner, ECG, ICU Equipment, Laboratory Equipment, Optoelectronic Equipment, Reagents, Hospital Furniture and other medical equipments & products. 
 
We welcome customers from all over the world visit our website or our company, and we assure you of our best quality products and services with competitive prices.Your cooperation with us will definitely create a win-win situation for both of us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now