Specifications

High Frequency   X-ray Machine:

Power Output                        : 26KW 
  Inverter Frequency               : 60kHz 
  X-Ray Tube                          : XD56-11 32/130 
  Dual-focus                   : Small focus: 0.6       Large focus: 1.3

Thermal capacity             :900kJ (1200 KHU) 
  The speed of the rotary anode   :   3000rpm 
  Tube Voltage                        : 40~130kV 
  Tube Current                          : 200mA 
  mAs                                   : 0.4~360mAs

Digital image   processing system: 
  Digital Detector:

Type of detector               :CCD

Field of view                 :17*17 Inch

Pixel                       :4K*4K

Spatial resolution             : ≥3.0LP/mm

Limit of spatial resolution       :4.6LP/mm

Pixel size                    :108um

Grayscale output             :14bit

Imaging time :7S

System control:

Image processing system : Photo   processing software, X-ray synchro Control software, motion control software

Image   post-processing     : tissue equilibrium,W/L adjustment,Gamma   correction, interest district, reversed phase, noise reduction, smooth,   sharpen,pseudo color, Edge extraction, shadow compensation, filter neuclear,   single window,dual-window, four windows, movement, right rotated 90°,left   rotated 90°,level mirror image,vertical mirror image, magnifying glass, image   zooming, reset, layer information, label character, drawing label, length measurement,   angle measurement,rectangular length, rectangular area, elliptic length,   elliptic area   

Image storage and transmission    : 

Dicom direct   transmission,

Dicom Worksite SCU,   standard

Dicom, DIR, film printing, mass   storage(hard disk, compact disk)

Mechanical structure   performance:

U-shaped arm:

Motorized vertical travel   : 450mm-1700mm(motorized control)

Anode to Screen range     : 1000mm-1800mm(motorized control)

Rotation range             : -40°~+130°(motorized control)

Photography bed   :

Bed size                   :2000mm*650mm

Bed height                 :≤720mm

Transervse shift             : 200mm(±100mm,   electromagnetic lock)

Longitudinal shift           : 100mm(±50mm,   electromagnetic lock)

Power   supply           : 380V 50HZ (220V 50HZ   is also available)

Features:

    The   electric lift and rotatable newly designed U-shaped frame can meet the   photographic requirements of different standing and lying positions. The   U-shaped design can make the operation much more convenient and flexible.The   world leading 1700 pixels digital CCD detector can help you get the   high-definition images.The   leading domestic high power compact high frequency X-ray generator and high   frequency power inverter makes the machine much more compact and more   convenient without the extra high-voltage generator and cable.Newly   designed photographic bed used specially for the U-shaped arm X-ray machine.   The bed floating and electromagnetic lock design makes it convenient for the   accurate position of the lying patient.Specially   designed working station for DR adopts all-digital   intelligent touchable LCD control system which is graphic and real color.   This system makes the operation easier and more convenient.Apply   different photographic parameters according to the human characteristics,   such as multi-site, multi-position, muti-body shape, adult and children etc. The   parameters can be modified and stored at will and make the operation more   convenient.The   high quality high frequency high-voltage X-ray generator and high frequency   power inverter can produce high-definition and good contrast images by high   quality radiation and low dose.

8. The application of the KV and MA digital   closed-loop control technology and the real time control of the   microprocessor ensure the accuracy and repeatability of the dose.

9. The multiple automatic protection features   and fault tips ensure safety during the operation process.

10 Support Dicom 3.0.

11. High quality battery is available for the   power supply. Normally, about 200 exposure is available after the battery is   fully charged. The image quality is stable and reliable without the effect of   the net power.

Intended use

Applied to the chest, skull, spine and limbs and other parts of the X-ray digital imaging

Features

1, The electric lift and rotatable newly designed U-shaped frame can meet the photographic requirements of different standing and lying positions. The U-shaped design can make the operation much more convenient and flexible.

2, The world leading 17 million and 9.8 million pixels digital CCD detector can help you get the high-definition images.

3, The leading domestic high power compact high frequency X-ray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.

4, Newly designed photographic bed used specially for the U-shaped arm X-ray machine. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient.

5, Specially designed working station for DR adopts all-digital intelligent touchable LCD control system which is graphic and real color. This system makes the operation easier and more convenient.

6, Apply different photographic parameters according to the human characteristics, such as multi-site, multi-position, muti-body shape, adult and children etc. The parameters can be modified and stored at will and make the operation more convenient.

7, The high quality high frequency high-voltage X-ray generator and high frequency power inverter can produce high-definition and good contrast images by high quality radiation and low dose.

8, The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.

9, The multiple automatic protection features and fault tips ensure safety during the operation process.

10, Support Dicom 3.0.

11, High quality battery is available for the power supply. Normally, about 200 exposure is available after the battery is fully charged. The image quality is stable and reliable without the effect of the net power.

System performance and parameters

Clause/ Specification

 

 

 

Section A

Main Digital Radiography System

1.0

X-ray Generator

Each set of X-ray generator unit for general radiography with at   least the following features:

1.1

3-phase ,high frequency converter / inverter, multi-pulse and   microprocessor control

1.2

Nominal power output 25KW

1.3

Tube current output of 200mA ,0.4mAs~360mAs

1.6

Exposure time range :from 2 ms or shorter to 2 seconds or longer

1.7

Suitable to operation of dual-focus X-ray tube : Large Focus :1.3mm,Small Focus :0.6 mm

1.8

Solid-state rectification

1.9

Automatic line voltage compensation

1.10

Automatic exposure control with manual override

1.11

Digital display of operator pre-set exposure data

1.12

Digital display of actual exposure data after X-ray exposure

1.13

Self-diagnostic functions with digital display of error codes

1.14

Tube-overload indication and protection on the control panel

1.15

User programmed radiographic exposure techniques with the   following features:

1.15.1

To be provided with at least 150   organ-related anatomical programmes to cover the whole body

1.15.2

Each exposure programme shall include at least 2 additional   selections for appropriate patient size compensation

1.15.3

The exposure programmes shall be user programmable

1.15.4

Selection of exposure programmes shall be by touch-controls or   push button controls

1.15.5

Alphanumeric display of selected anatomical exposure programme

1.15.6

Integrated radiation exposure switch on generator control console

1.17

All necessary protective circuits shall be incorporated .

2.0

X-ray Tube

Each set of rotation anode X-ray tube to be mounted to the Tube   Carries System with at least the following features:

2.1

Dual focus with focal spot sizes of 0.6 mm and   focus 1.3mm

2.2

Tube voltage 125 kV

2.3

Anode heat storage capacity is 300 KHU

2.4

Safety circuitry to prevent over heating with indication on   control console of X-ray generator

3.1

Collimator

Each set of light beam   collimator to is mounted onto the Tube Unit with below features :Manually   adjustable diaphragms with indicator/readings of beam coverage at selected   Source-Image-Distance(SID)

3.2

Automatic collimation according to examination selected, can be   overridden manually

3.3

Optical centering indication for positioning and side beam for   central alignment of X-ray beam with detector assembly

3.4

Receptacle channels(s)/track(s) for insertion of external filters.   A full set of dedicated filters, with filter holder for attachment to the collimator,   has to be provided for exposure compensation for various anatomical regions   such as skull , shoulder, spine and chest etc

3.5

A built-in electronic or mechanical measuring device for   measurement of SID is incorporated

3.6

Provision of dose reduction filters , which are operator   selectable or automatic for filtering of low energy radiation

3.7

Integrated display/multi-functional control panel over X-ray tube   housing with at least the following features:

3.8

Selection of target detector :

-            Table

-            Wall stand

-            Table top for free exposure

4.1

All movements of the tube assembly can be manually operated and   are provided with electro-magnetic brakes.

4.2

Automatic height adjustment of X-ray tube to maintain constant   focus to tabletop distance when table height changes.

4.3

Automatic centering of X-ray tube to remain centre to the vertical   detector when the height of detector assembly changes

4.4

Automatic longitudinal detector tracking.

4.4

Remote control of automatic detector tracking

4.4

Auto-positioning function shall be provided

4.7

It can be controlled at the acquisition workstation or at other   convenient facility such as hand control .

4.8

Safety mechanism to prevent the X-ray tube or the column assembly   from failing in case of lock, springs or cables failure.

4.9

Vertical axis: -40°~+130°.

5.0

PLX153 Radiographic Imaging Table with the following features:

5.1

Four-way floating ,non-transparent flat   tabletop with electro-magnetic brakes for tabletop movements and   motorized height adjustment.

5.2

Foot switch(es) built-in to the table base for brake release of   tabletop movements and height adjustment,

5.3

Safety interlock/device to stop tabletop movement when footswitch   is inadvertently stepped on

5.4

Collision prevention device to stop tabletop vertical movement if lowers onto any obstruction

5.5

Table-top movement range

5.6

Longitudinal: ±200mm, Transverse: no less than ±100 mm, Size of the table is 2000x650mm. Patient weight carrying capacity of tabletop   is 200kg Lowest table height,

5.7

Integrated with the CCD detector

5.8

Equipped with a removable, oscillating grid ,grid ratio 10:1

5.9

Bucky assembly have a vertical movement range of 470mm~1468mm

6.0

The table detector shall have the following features:

6.1

Data acquisition is 14 bits per pixel

6.2

Image resolution is at least 4.6 lp/mm,7 seconds imaging

7.0

Image Acquisition console

One set of Image Acquisition Console for each unit of Digital   Radiography Imaging System on offer is provided and installed with the   following performance for X-ray control ,image acquisition, processing and   display

7.1

High-end PC processor with network capability . PC processor of   highest processing capacity .

7.2

It can be connected to and control the operation of the generator   system and be able to control the image acquisition parameters

7.3

The image Acquisition Console support DICOM Worklist SCU, Able to   accept accession number from PACS,Dicom DIR,Film printer, mass storage , DICOM 3.0 with conformance statements DICOM   Send, SCU, DICOM Print,SCU, DICOM Storage,SCU, DICOM Storage commitment,SCU

7.4

Different formats of images can be selected for printing

7.5

19" LCD monitor , of resolution not less than 1280 x 1024,for image   display . Keyboard ,mouse and barcode reader are provided for data entry.


About us

Refine Medical Technology Co., Ltd. was founded in Nanjing, China with the goal to supply medical products with high quality, competitive price and excellent after-sales service.
 
As the leading professional manufacturer & exporter of medical equipment, Refine Medical own a group of very professional technical and sales staff with the high efficiency, who are able to provide the customers complete range of service. Being approved with CE,ISO, Certificate, etc. We have established efficient worldwide network of marketing. In the past 15 years, we have exported our products to more than 120 countries all over the world. 
 
Refine Medical product range covers X-ray machines, Ultrasound Scanner, ECG, ICU Equipment, Laboratory Equipment, Optoelectronic Equipment, Reagents, Hospital Furniture and other medical equipments & products. 
 
We welcome customers from all over the world visit our website or our company, and we assure you of our best quality products and services with competitive prices.Your cooperation with us will definitely create a win-win situation for both of us.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now