Customized: | Non-Customized |
---|---|
Certification: | CE, ISO13485 |
Scale: | Large |
Transport Package: | Standard Packaging |
Trademark: | RF |
Origin: | Jiangsu, China |
Customization: |
---|
Suppliers with verified business licenses
Specifications |
High Frequency X-ray Machine: Power Output : 26KW Thermal capacity :900kJ (1200 KHU) Digital image processing system: Type of detector :CCD Field of view :17*17 Inch Pixel :4K*4K Spatial resolution : ≥3.0LP/mm Limit of spatial resolution :4.6LP/mm Pixel size :108um Grayscale output :14bit Imaging time :7S System control: Image processing system : Photo processing software, X-ray synchro Control software, motion control software Image post-processing : tissue equilibrium,W/L adjustment,Gamma correction, interest district, reversed phase, noise reduction, smooth, sharpen,pseudo color, Edge extraction, shadow compensation, filter neuclear, single window,dual-window, four windows, movement, right rotated 90°,left rotated 90°,level mirror image,vertical mirror image, magnifying glass, image zooming, reset, layer information, label character, drawing label, length measurement, angle measurement,rectangular length, rectangular area, elliptic length, elliptic area Image storage and transmission : Dicom direct transmission, Dicom Worksite SCU, standard Dicom, DIR, film printing, mass storage(hard disk, compact disk) Mechanical structure performance: U-shaped arm: Motorized vertical travel : 450mm-1700mm(motorized control) Anode to Screen range : 1000mm-1800mm(motorized control) Rotation range : -40°~+130°(motorized control) Photography bed : Bed size :2000mm*650mm Bed height :≤720mm Transervse shift : 200mm(±100mm, electromagnetic lock) Longitudinal shift : 100mm(±50mm, electromagnetic lock) Power supply : 380V 50HZ (220V 50HZ is also available) Features:
8. The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose. 9. The multiple automatic protection features and fault tips ensure safety during the operation process. 10 Support Dicom 3.0. 11. High quality battery is available for the power supply. Normally, about 200 exposure is available after the battery is fully charged. The image quality is stable and reliable without the effect of the net power. |
Applied to the chest, skull, spine and limbs and other parts of the X-ray digital imaging
Features
1, The electric lift and rotatable newly designed U-shaped frame can meet the photographic requirements of different standing and lying positions. The U-shaped design can make the operation much more convenient and flexible.
2, The world leading 17 million and 9.8 million pixels digital CCD detector can help you get the high-definition images.
3, The leading domestic high power compact high frequency X-ray generator and high frequency power inverter makes the machine much more compact and more convenient without the extra high-voltage generator and cable.
4, Newly designed photographic bed used specially for the U-shaped arm X-ray machine. The bed floating and electromagnetic lock design makes it convenient for the accurate position of the lying patient.
5, Specially designed working station for DR adopts all-digital intelligent touchable LCD control system which is graphic and real color. This system makes the operation easier and more convenient.
6, Apply different photographic parameters according to the human characteristics, such as multi-site, multi-position, muti-body shape, adult and children etc. The parameters can be modified and stored at will and make the operation more convenient.
7, The high quality high frequency high-voltage X-ray generator and high frequency power inverter can produce high-definition and good contrast images by high quality radiation and low dose.
8, The application of the KV and MA digital closed-loop control technology and the real time control of the microprocessor ensure the accuracy and repeatability of the dose.
9, The multiple automatic protection features and fault tips ensure safety during the operation process.
10, Support Dicom 3.0.
11, High quality battery is available for the power supply. Normally, about 200 exposure is available after the battery is fully charged. The image quality is stable and reliable without the effect of the net power.
System performance and parameters
Clause/ Specification |
|
|
|
Section A |
Main Digital Radiography System |
1.0 |
X-ray Generator Each set of X-ray generator unit for general radiography with at least the following features: |
1.1 |
3-phase ,high frequency converter / inverter, multi-pulse and microprocessor control |
1.2 |
Nominal power output 25KW |
1.3 |
Tube current output of 200mA ,0.4mAs~360mAs |
1.6 |
Exposure time range :from 2 ms or shorter to 2 seconds or longer |
1.7 |
Suitable to operation of dual-focus X-ray tube : Large Focus :1.3mm,Small Focus :0.6 mm |
1.8 |
Solid-state rectification |
1.9 |
Automatic line voltage compensation |
1.10 |
Automatic exposure control with manual override |
1.11 |
Digital display of operator pre-set exposure data |
1.12 |
Digital display of actual exposure data after X-ray exposure |
1.13 |
Self-diagnostic functions with digital display of error codes |
1.14 |
Tube-overload indication and protection on the control panel |
1.15 |
User programmed radiographic exposure techniques with the following features: |
1.15.1 |
To be provided with at least 150 organ-related anatomical programmes to cover the whole body |
1.15.2 |
Each exposure programme shall include at least 2 additional selections for appropriate patient size compensation |
1.15.3 |
The exposure programmes shall be user programmable |
1.15.4 |
Selection of exposure programmes shall be by touch-controls or push button controls |
1.15.5 |
Alphanumeric display of selected anatomical exposure programme |
1.15.6 |
Integrated radiation exposure switch on generator control console |
1.17 |
All necessary protective circuits shall be incorporated . |
2.0 |
X-ray Tube Each set of rotation anode X-ray tube to be mounted to the Tube Carries System with at least the following features: |
2.1 |
Dual focus with focal spot sizes of 0.6 mm and focus 1.3mm |
2.2 |
Tube voltage 125 kV |
2.3 |
Anode heat storage capacity is 300 KHU |
2.4 |
Safety circuitry to prevent over heating with indication on control console of X-ray generator |
3.1 |
Collimator Each set of light beam collimator to is mounted onto the Tube Unit with below features :Manually adjustable diaphragms with indicator/readings of beam coverage at selected Source-Image-Distance(SID) |
3.2 |
Automatic collimation according to examination selected, can be overridden manually |
3.3 |
Optical centering indication for positioning and side beam for central alignment of X-ray beam with detector assembly |
3.4 |
Receptacle channels(s)/track(s) for insertion of external filters. A full set of dedicated filters, with filter holder for attachment to the collimator, has to be provided for exposure compensation for various anatomical regions such as skull , shoulder, spine and chest etc |
3.5 |
A built-in electronic or mechanical measuring device for measurement of SID is incorporated |
3.6 |
Provision of dose reduction filters , which are operator selectable or automatic for filtering of low energy radiation |
3.7 |
Integrated display/multi-functional control panel over X-ray tube housing with at least the following features: |
3.8 |
Selection of target detector : - Table - Wall stand - Table top for free exposure |
4.1 |
All movements of the tube assembly can be manually operated and are provided with electro-magnetic brakes. |
4.2 |
Automatic height adjustment of X-ray tube to maintain constant focus to tabletop distance when table height changes. |
4.3 |
Automatic centering of X-ray tube to remain centre to the vertical detector when the height of detector assembly changes |
4.4 |
Automatic longitudinal detector tracking. |
4.4 |
Remote control of automatic detector tracking |
4.4 |
Auto-positioning function shall be provided |
4.7 |
It can be controlled at the acquisition workstation or at other convenient facility such as hand control . |
4.8 |
Safety mechanism to prevent the X-ray tube or the column assembly from failing in case of lock, springs or cables failure. |
4.9 |
Vertical axis: -40°~+130°. |
5.0 |
PLX153 Radiographic Imaging Table with the following features: |
5.1 |
Four-way floating ,non-transparent flat tabletop with electro-magnetic brakes for tabletop movements and motorized height adjustment. |
5.2 |
Foot switch(es) built-in to the table base for brake release of tabletop movements and height adjustment, |
5.3 |
Safety interlock/device to stop tabletop movement when footswitch is inadvertently stepped on |
5.4 |
Collision prevention device to stop tabletop vertical movement if lowers onto any obstruction |
5.5 |
Table-top movement range |
5.6 |
Longitudinal: ±200mm, Transverse: no less than ±100 mm, Size of the table is 2000x650mm. Patient weight carrying capacity of tabletop is 200kg Lowest table height, |
5.7 |
Integrated with the CCD detector |
5.8 |
Equipped with a removable, oscillating grid ,grid ratio 10:1 |
5.9 |
Bucky assembly have a vertical movement range of 470mm~1468mm |
6.0 |
The table detector shall have the following features: |
6.1 |
Data acquisition is 14 bits per pixel |
6.2 |
Image resolution is at least 4.6 lp/mm,7 seconds imaging |
7.0 |
Image Acquisition console One set of Image Acquisition Console for each unit of Digital Radiography Imaging System on offer is provided and installed with the following performance for X-ray control ,image acquisition, processing and display |
7.1 |
High-end PC processor with network capability . PC processor of highest processing capacity . |
7.2 |
It can be connected to and control the operation of the generator system and be able to control the image acquisition parameters |
7.3 |
The image Acquisition Console support DICOM Worklist SCU, Able to accept accession number from PACS,Dicom DIR,Film printer, mass storage , DICOM 3.0 with conformance statements DICOM Send, SCU, DICOM Print,SCU, DICOM Storage,SCU, DICOM Storage commitment,SCU |
7.4 |
Different formats of images can be selected for printing |
7.5 |
19" LCD monitor , of resolution not less than 1280 x 1024,for image display . Keyboard ,mouse and barcode reader are provided for data entry. |
About us
Refine Medical Technology Co., Ltd. was founded in Nanjing, China with the goal to supply medical products with high quality, competitive price and excellent after-sales service.
As the leading professional manufacturer & exporter of medical equipment, Refine Medical own a group of very professional technical and sales staff with the high efficiency, who are able to provide the customers complete range of service. Being approved with CE,ISO, Certificate, etc. We have established efficient worldwide network of marketing. In the past 15 years, we have exported our products to more than 120 countries all over the world.
Refine Medical product range covers X-ray machines, Ultrasound Scanner, ECG, ICU Equipment, Laboratory Equipment, Optoelectronic Equipment, Reagents, Hospital Furniture and other medical equipments & products.
We welcome customers from all over the world visit our website or our company, and we assure you of our best quality products and services with competitive prices.Your cooperation with us will definitely create a win-win situation for both of us.
Suppliers with verified business licenses